Share:


Study on seismic response of a new staggered story isolated structure considering SSI effect

    Dewen Liu Affiliation
    ; Liping Li Affiliation
    ; Yafei Zhang Affiliation
    ; Lihao Chen Affiliation
    ; Feng Wan Affiliation
    ; Fan Yang Affiliation

Abstract

The new staggered story isolated structure is a new type of seismic isolated structure developed from base isolated structure and inter-story isolated structure. In order to explore the seismic response of the new staggered story isolated structure considering the soil-structure interaction (SSI), the model of a new staggered story isolated structure considering SSI effect is established to analyze the nonlinear dynamic time-history response under rare earthquakes, and the comparison between hard soil and soft soil was carried out. Results show that the stiffness of the new staggered story isolated structure reduced, the modal period extended and the seismic response reduced by considering the SSI effect, the softer the site soil, the more obvious those changes are. Meanwhile, the shear force and the damage of the core tube decreases, while the shear force and the damage of the frame increases, the shear force transfers from the core tube to the frame. Additionally, the energy absorption of the seismic isolated bearings at the frame reduced, the energy absorption of the seismic isolated bearings at the core tube increased, the softer the site soil, the more obvious the trend is.

Keyword : SSI effect, new staggered story isolated structure, vibration absorption, damage

How to Cite
Liu, D., Li, L., Zhang, Y., Chen, L., Wan, F., & Yang, F. (2022). Study on seismic response of a new staggered story isolated structure considering SSI effect. Journal of Civil Engineering and Management, 28(5), 397–407. https://doi.org/10.3846/jcem.2022.16825
Published in Issue
May 3, 2022
Abstract Views
1004
PDF Downloads
506
Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

References

Castaldo, P., & Tubaldi, E. (2018). Influence of ground motion characteristics on the optimal single concave sliding bearing properties for base-isolated structures. Soil Dynamics & Earthquake Engineering, 104, 346–364. https://doi.org/10.1016/j.soildyn.2017.09.025

Chang, P. J., & Zhu, J. (2011). Seismic vulnerability analysis of mid-story isolation and reduction structures based stochastic vibration. Advanced Materials Research, 243–249, 3988–3991. https://doi.org/10.4028/www.scientific.net/AMR.243-249.3988

Computers and Structures Inc. (2007). Analysis reference manual for SAP2000, ETABS, and SAFE.

Karabork, T., Deneme, I. O., & Bilgehan, R. P. (2014). A comparison of the effect of SSI on base isolation systems and fixed-base structures for soft soil. Geomechanics and Engineering, 7(1), 87–103. https://doi.org/10.12989/gae.2014.7.1.087

Kelly, J. M. (2012). Base isolation: Linear theory and design. Earthquake Spectra, 6(2), 223–244. https://doi.org/10.1193/1.1585566

Kubin, J., Kubin, D., Özmen, A., Şadan, O. B., & Eroglu, E. (2012). Seismic retrofit of an existing multi-block hospital by seismic isolators. In Proceedings of the 15th World Conference on Earthquake Engineering, Lisbon, Portugal.

Li, H., Wang, Y. N., & Du, Y. F. (2012). Influence of soil structure dynamic interaction on base isolated structure. Earthquake Resistant Engineering and Retrofitting, 34(1), 37–41.

Liu, W. Q., Li, C. P., Wang, S. G., Du, D. S., & Wang, H. (2013). Comparative study on high-rise isolated structure founded on various soil foundation by using shaking table tests. Journal of Vibration and Shock, 32(16), 128–133.

Liufu, J., Lin, S. M., & Huang, Z. H. (2020). Structural scheme selection and design of an isolated high-rise building structure with a large chassis and multiple tower-layer in a high-intensity region. Building Structure, 50(10), 83–89.

Loh, C. H., Weng, J. H., Chen, C. H., & Lu, K. C. (2013). System identification of mid‐story isolation building using both ambient and earthquake response data. Structural Control and Health Monitoring, 20(2), 139–155. https://doi.org/10.1002/stc.479

Ministry of Housing and Urban-rural Construction of the People’s Republic of China and the General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China. (2016). Code for seismic design of buildings (No. GB 50011-2010). China Architecture & Building Press.

National Institute of Standards and Technology. (2012). Soil-structure interaction for building structures (Report No. NIST/GCR 11-917).

Qi, Y. N., Sun, R., Guan, Q. S., & Zeng, C. W. (2020). Application of new type anti-tension device in high aspect ratio isolation structure design. Earthquake Resistant Engineering and Retrofitting, 42(4), 93–98.

Shan, J., Shi, Z., Gong, N., & Shi, W. (2020). Performance improvement of base isolation systems by incorporating eddy current damping and magnetic spring under earthquakes. Structural Control and Health Monitoring, 27(6), e2524. https://doi.org/10.1002/stc.2524

Shang, S. P., & Hu, L. H. (2020). Analysis of energy dissipation characteristics of base isolation structures. Earthquake Engineering and Engineering Dynamics, 40(1), 12–21.

Su, Y., Li, J. Z., He, Q., Bao, X., & Li, A. Q. (2015). Related parameter analysis of story isolation structure considering soil-structure interaction. Industrial Construction, 45(11), 9–13.

Wang, Y. R., Dai, J. W., Zhan, S. M., & Jiang, Y. (2008). A numerical analysis based substitute method for shaking table test in considering of the soil-structure interaction. In The 14th World Conference on Earthquake Engineering, Beijing, China.

Zhang, Y. Q. (2019, December 2). Seismic artifact for high-rise buildings in our city. Baotou Daily, 7.

Zhang, Y., Yi, W. J., Tan, P., & Zhou, F.-L. (2009). The dynamic reliability of mid-story isolation structure under seldomly occurred earthquake. Journal of Hunan University (Natural Sciences), 36(3), 11–15.

Zhang, S. R., Tan, P., Du, Y. F., Bao, C., & Zhou, F. L. (2014). Effect analysis of soil-structure interaction on inter-story isolation structure. China Civil Engineering Journal, 47(S1), 246–252.

Zhou, Q., Singh, M. P., & Huang, X. (2016). Model reduction and optimal parameters of mid-story isolation systems. Engineering Structures, 124, 36–48. https://doi.org/10.1016/j.engstruct.2016.06.011

Zhou, Y., Li, X., & Chen, Z. (2018). Seismic responses analysis of base-isolated LNG storage tank. In Proceedings of GeoShanghai 2018 International Conference: Advances in Soil Dynamics and Foundation Engineering, Shanghai, China. https://doi.org/10.1007/978-981-13-0131-5_36

Zhuang, H. Y., Yu, X., Zhu, C., & Jin, D. (2014). Shaking table tests for the seismic response of a base-isolated structure with the SSI effect. Soil Dynamics and Earthquake Engineering, 67, 208–218. https://doi.org/10.1016/j.soildyn.2014.09.013